ROLE OF DIFFERENT PULSE SEQUENCES FOR BETTER CONTRAST USING MAGNETIC RESONANCE IMAGING.

  • Department of Physics, The Islamia University of Bahawalpur. Pakistan.
Crossref Cited-by Linking logo
  • Abstract
  • Keywords
  • References
  • Cite This Article as
  • Corresponding Author

This research study aimed to compare the image quality and contrast using different pulse sequences and to evaluate practical impact and efficacy of altering imaging parameters on image quality using magnetic resonance imaging. A tissue equivalent dosimeter gel system by using Xylenol orange dye with Fricke-Benzoic solution was developed and the gel system was irradiated using 6MV photons. Conventional spin echo (CSE), Fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) pulse sequences were used to analyze the effect of TR (repetition-time) and TE (echo-time) on contrast to noise ratio (CNR). The calculated percentage increase of contrast to noise ratio (CNR) for TR using pulse sequences CSE, FSE, GRE and FLAIR was 8%, 10%, 6% and 4% and the percentage decrease for TE is 3%, 4%, 5% and 11% respectively. The qualitative analysis include the effect of TR and TE on contrast to noise ratio according to which the increasing repetition time gives good contrast to noise ratio especially for conventional and fast spin echo sequence. It is better to keep echo time lower but this is an imperceptible parameter for contrast to noise ratio for T1-weighted images.


  1. Bartusek, K. and Z. Smekal (2006). "Processing of MR images weighted by relaxation time T2 to increase their resolution."
  2. Bucholz, E., K. Ghaghada, et al. (2008). "Four?dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent." Magnetic resonance in medicine 60(1): 111-118.
  3. Damadian, R. (1971). "Tumor detection by nuclear magnetic resonance."
  4. De Deene, Y. (2009). Review of quantitative MRI principles for gel dosimetry. Journal of Physics: Conference Series, IOP Publishing.
  5. Gore, J. and Y. Kang (1984). "Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging." Physics in medicine and biology 29(10): 1189.
  6. Li, T. and S. A. Mirowitz (2003). "Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts." Magnetic resonance imaging 21(7): 745-753.
  7. Maeyama, T., N. Fukunishi, et al. (2014). "A diffusion-free and linear-energy-transfer-independent nanocomposite Fricke gel dosimeter." Radiation Physics and Chemistry 96: 92-96.
  8. Riddell, A., C. Richardson, et al. (2014). "The development and optimization of high spatial resolution MRI for imaging the oesophagus using an external surface coil." The British journal of radiology.
  9. Sullivan, E. V., E. Adalsteinsson, et al. (2006). "Longitudinal Brain Magnetic Resonance Imaging Study of the Alcohol?Preferring Rat. Part I: Adult Brain Growth." Alcoholism: Clinical and Experimental Research 30(7): 1234-1247.
  10. Yamada, K., E. R. Wisner, et al. (2002). "Technical parameters affecting image characteristics in in vivo MR microscopy of the mouse." Veterinary Radiology & Ultrasound 43(6): 518-527.

[Aalia Nazir, Muhammad Waqas Akhtar and Zahida Batool. (2017); ROLE OF DIFFERENT PULSE SEQUENCES FOR BETTER CONTRAST USING MAGNETIC RESONANCE IMAGING. Int. J. of Adv. Res. 5 (Feb). 226-232] (ISSN 2320-5407). www.journalijar.com


Muhammad Waqas Akhtar
Department of Physics, The Islamia university of Bahawalpur. Pakistan

DOI:


Article DOI: 10.21474/IJAR01/3136      
DOI URL: http://dx.doi.org/10.21474/IJAR01/3136