30Mar 2017

STEREOMICROSCOPIC EVALUATION OF DENTINAL DAMAGE CAUSED BY K-FILES, PROTAPER UNIVERSAL, NEONITI A1 AND iRaCe FILES-AN IN VITRO STUDY

  • Abstract
  • Keywords
  • References
  • Cite This Article as
  • Corresponding Author

Aim: To compare the dentinal damage induced by stainless steel hand and rotary nickel-titanium instruments using K files, ProTaper Universal, Neoniti A1 and iRaCe files. Materials and Methods: Sixty single rooted premolars were collected and randomly divided into four groups of 15 teeth each. Group 1- Stainless steel K Files, group 2–ProTaper Universal, group 3- Neoniti A1 file and group 4 - iRaCe rotary instruments. Cleaning and shaping was done with the respective files. The roots were then cut horizontally at 3mm, 6mm and 9 mm from apex and were examined under stereomicroscope. The sections were checked for dentinal defects. Statistical analysis: Groups were analysed with the Fishers exact test. Results: It was found that all instruments examined caused dentinal defects with maximum defects in the apical third. Neoniti A1 file showed least number of dentinal defects compared to other file systems. Conclusion: The present study revealed that all the instruments could result in an increased chance for dentinal defects.


  1. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. Journal of endodontics. 2004 Aug 31;30(8):559-67.
  2. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Smooth flexible versus active tapered shaft design using NiTi rotary instruments. International Endodontic Journal. 2002 Oct 1;35(10):820-8.
  3. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974;18:269-96.
  4. Yared G. Canal preparation using only one Ni?Ti rotary instrument: preliminary observations. International endodontic journal. 2008 Apr 1;41(4):339-44.
  5. Singh S, Nigam N. Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file. Journal of Conservative Dentistry. 2010 Apr 1;13(2):89.
  6. Ruddle CJ, Machtou P, West JD. The shaping movement 5th generation technology. Dent Today. 2013 Apr;32(4):94.
  7. Gupta R, Dhingra A, Aggarwal N, Yadav V. A new approach to single file endodontics: Neoniti rotary file system. Int J Advances In Case Reports. 2015;2(16):1030-2.
  8. Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single?file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. International Endodontic Journal. 2012 May 1;45(5):449-61.
  9. Saber SE, Nagy MM, Schäfer E. Comparative evaluation of the shaping ability of ProTaper Next, iRaCe and Hyflex CM rotary NiTi files in severely curved root canals. International endodontic journal. 2015 Feb 1;48(2):131-6.
  10. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Smooth flexible versus active tapered shaft design using NiTi rotary instruments. International Endodontic Journal. 2002 Oct 1;35(10):820-8.
  11. Tamse A, Fuss Z, Lustig J, Kaplavi J. An evaluation of endodontically treated vertically fractured teeth. Journal of endodontics. 1999 Jul 1;25(7):506-8.
  12. Pitts DL, Natkin E. Diagnosis and treatment of vertical root fractures. Journal of endodontics. 1983 Aug 1;9(8):338-46.
  13. Ceyhanli KT, Erdilek N, Tatar I, Celik D. Comparison of ProTaper, RaCe and Safesider instruments in the induction of dentinal microcracks: a micro?CT study. International endodontic journal. 2015 Jul 1.
  14. Kumar VR, Bahuguna N, Manan R. Comparison of efficacy of various root canal irrigation systems in removal of smear layer generated at apical third: An SEM study. Journal of conservative dentistry: JCD. 2015 May;18(3):252.
  15. Wilcox LR, Roskelley C, Sutton T. The relationship of root canal enlargement to finger-spreader induced vertical root fracture. Journal of Endodontics. 1997 Aug 1;23(8):533-4.
  16. Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file. Journal of endodontics. 2012 Feb 29;38(2):232-5.
  17. Ashraf F, Shankarappa P, Misra A, Sawhney A, Sridevi N, Singh A. A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study. Scientifica. 2016 Jun 29;2016.
  18. Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation. Journal of Endodontics. 2009 Feb 28;35(2):236-8.
  19. Helvacioglu-Yigit D, Aydemir S, Yilmaz A. Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study. Biotechnology & Biotechnological Equipment. 2015 Mar 4;29(2):368-73.
  20. Shemesh H, Bier CA, Wu MK, Tanomaru?Filho M, Wesselink PR. The effects of canal preparation and filling on the incidence of dentinal defects. International Endodontic Journal. 2009 Mar 1;42(3):208-13.
  21. Adorno CG, Yoshioka T, Suda H. Crack initiation on the apical root surface caused by three different nickel-titanium rotary files at different working lengths. Journal of endodontics. 2011 Apr 30;37(4):522-5.
  22. Thompson SA. An overview of nickel–titanium alloys used in dentistry. International endodontic journal. 2000 Jul 1;33(4):297-310.
  23. Adorno CG, Yoshioka T, Suda H. The effect of working length and root canal preparation technique on crack development in the apical root canal wall. International endodontic journal. 2010 Apr 1;43(4):321-7.
  24. Kuttler Y. Microscopic investigation of root apexes. The Journal of the American Dental Association. 1955 May 1;50(5):544-52.
  25. Ingle JI. Ingle’s Endodontics 6. 6th ed. Hamilton, Ontario: BC Decker; 2008. 938p
  26. Devale MR, Mahesh MC, Bhandary S. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation–An In vitro Study.
  27. Sathorn C, Palamara JE, Messer HH. A comparison of the effects of two canal preparation techniques on root fracture susceptibility and fracture pattern. Journal of Endodontics. 2005 Apr 30;31(4):283-7.
  28. Liu R, Kaiwar A, Shemesh H, Wesselink PR, Hou B, Wu MK. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Journal of endodontics. 2013 Jan 31;39(1):129-32.
  29. Gianluca G. The K3 rotary nickel titanium instrument system. Endodontic Topics. 2005 Mar 1;10(1):179-82.
  30. West JD. Introduction of a new rotary endodontic system: progressively tapering files. Dentistry today. 2001 May;20(5):50-2.
  31. Capar ID, Arslan H, Akcay M, Uysal B. Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin. Journal of endodontics. 2014 Sep 30;40(9):1482-4.
  32. McSpadden JT. Mastering endodontic instrumentation. Chattanooga, TN: Cloud land. Institute, 2007:51-52.
  33. Milani AS, Froughreyhani M, Rahimi S, Jafarabadi MA, Paksefat S. The effect of root canal preparation on the development of dentin cracks. Iranian endodontic journal. 2012 Oct 20;7(4):177-82.
  34. Jain A, Bhadoria K, Choudhary B,Patidar N. Comparison of Dentinal Defects induced by Hand Files, Multiple, and Single Rotary Files: A Stereomicroscopic Study. January 2017World Journal of Dentistry8(1):45-48.

[Arun Paul, Nithin Suvarna, K. Harish S. Shetty and Mohd. Nooh Khazia. (2017); STEREOMICROSCOPIC EVALUATION OF DENTINAL DAMAGE CAUSED BY K-FILES, PROTAPER UNIVERSAL, NEONITI A1 AND iRaCe FILES-AN IN VITRO STUDY Int. J. of Adv. Res. 5 (Mar). 1719-1725] (ISSN 2320-5407). www.journalijar.com


Dr. Arun Paul
Post Graduate Student, Dept. Of Conservative Dentistry And Endodontics, Yenepoya Dental College, Deralakatte,Mangalore Pin 575018

DOI:


Article DOI: 10.21474/IJAR01/3684      