EFFECT OF SPLINTING AND NON SPLINTING OF IMPRESSION TRANSFER DURING IMPRESSION MAKING ON THE FIT OF MULTI-IMPLANT SUPPORTED FIXED FULL ARCH FRAMEWORKS. SYSTEMATIC REVIEW AND META-ANALYSIS.
- Zakaria A: Ph.D researcher, removable prothodontic department, Faculty of dentistry, Cairo University.
- Kaddah AF: Professor of removable prothodontic, Faculty of dentistry, Cairo University.
- Fayyad AE: Associate Professor of removable prothodontic, Faculty of dentistry, Cairo University.
- Al-quitaiby AY: Ph.D removable prothodontic, Faculty of dentistry, Cairo University.
- Abstract
- References
- How to Cite This Article
- Corresponding Author
Statement of problem: The best impression technique should be followed during construction of prosthesis to eliminate poor fit of frameworks connected to implant to decrease undue stresses on the various elements. Purpose: The purpose of this review was to evaluate clinical studies comparing splinted and nonsplinted impression techniques regarding passive fit Materials and methods: An electronic search was performed in November 2017 of MEDLINE, and Cochrane Library databases with the key words implant, implants, impression, and impressions. To be included, the study had to investigate the passive fit of implant prosthesis. In addition, a hand search was performed to enrich the results for the time period from January 1980 to May 2017. After executing the search strategies, 3 articles were selected to be included in the review process. Results All of the selected articles were in clinical studies. Two studies preferred splinted over nonsplinted impressions. One study reported no difference. The meta-analysis of the three trials regarding framework fitting comparing splinted and non-splinted impression showed statistically non-significant more risk of misfit in none splinted technique when compared to splinted technique.
- Goll GE. Production of accurately fitting full-arch implant frameworks: Part I-Clinical procedures. J Prosthet Dent. 1991;66:377?384.
- Kallus T, Bessing C. Loose gold screws frequently occur in fullarch fixed prostheses supported by oseointegrated implants after 5 years. Int J Oral Maxillofac Implants. 1994;9:169?178.
- Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants. 1990;5:331?336.
- Henry PJ. An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J Prosthet Dent. 1987;58:694?697.
- Branemark PI, Zarb GA, Albrektsson T. Tissue-integrated prostheses. Osseointegration in clinical dentistry. Chicago: Quintessence; 1985. pp. 11?12.pp. 253?257.
- Inturregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent. 1993;69:503?509.
- Burawi G, Houston F, Byrne D, Claffey N. A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent. 1997;77:68?75
- Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent. 2007;16:187?194.
- Del?Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo FA Jr. Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 2008;23:226-36.
- Rangert B, Jemt T, J?rneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants. 1989;4:241?247.
- Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont. 1993;6:346?363.
- Moher, D; Liberati, A; Tetzlaff, J;, and DG Altman. 2010. ?Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement... Preferred Reporting Items for Systematic Reviews and Meta-Analyses.? BMJ: British Medical Journal (Overseas {&} Retired Doctors Edition) 8 (5): b2535. doi:10.1016/j.ijsu.2010.02.007.
- Law, C., Bennani, V., Lyons, K., and Swain, M., Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study. J Prosthet Dent, 2014.
- Chen, D.C., Lai, Y.L., Chi, L.Y., and Lee, S.Y., Contributing factors of mandibular deformation during mouth opening. J Dent, 2000. 28(8): p. 583-8.
- Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implant- supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-8.
- Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 2004;92:470-6
- Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66
- Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16:187-94
- Kim S, Nicholls JI, Han CH, Lee KW. Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 2006;21:747-55.\
- Choi JH, Lim YJ, Yim SH, Kim CW. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implants 2007;22:761-8.
- Del?Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fd A Jr. Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants. 2008;23:226-36.
- Panos Papaspyridakos, Kunal Lal, George Shelby White, Hans-Peter Weber, German O Gallucci. Effect of splinted and nonsplinted Impression Techniques on the Accuracy of fit of fixed implant prostheses in Edentulous Patients: A Comparative study. Int J Oral Maxillofac Implants. 2011; 26;1267-1272.
- Michael Perez-Davidi, Michael Levit, Ofer Walter, Yuval Eilat, Peter Rosenfeld. Clinical accuracy outcomes of splinted and nonsplinted implant impression methods in dental residency settings. Quintessence Int J Prosth. 2016;47;843-852.
- Yosry Moh. , EL Far Mahm. , EL Khadem Amr. The effect of two impression techniques on the fit of screw retained implant frameworks. MDS thesis, Faculty of dentistry, Cairo University. 2012.
Zakaria A, Kaddah AF, Fayyad AE and Al-quitaiby AY. (2017); EFFECT OF SPLINTING AND NON SPLINTING OF IMPRESSION TRANSFER DURING IMPRESSION MAKING ON THE FIT OF MULTI-IMPLANT SUPPORTED FIXED FULL ARCH FRAMEWORKS. SYSTEMATIC REVIEW AND META-ANALYSIS., Int. J. of Adv. Res., 5 (12), 1082-1088, ISSN 2320-5407. DOI URL: https://dx.doi.org/10.21474/IJAR01/6060
Ph.D researcher






