22Jun 2019

A NEW REACTOR GEOMETRY TO TREATMENT IN SCALE OF BIOMEDICAL SURFACES BY PLASMA ELECTROLYTIC OXIDATION.

  • Federal University of Rio Grande do Norte, Natal/RN - Brazil.
Crossref Cited-by Linking logo
  • Abstract
  • Keywords
  • References
  • Cite This Article as
  • Corresponding Author

The state of the art report many studies seeking for biocompatible materials for manufacturing and processing of implants, mainly, for orthopedic and dental care. A wide spectrum of surface modification techniques are available, such as chemical vapor deposition, anodizing, plasma spraying and plasma electrolytic oxidation (PEO). Among these techniques, PEO is an attractive technique for biomedical applications once that its characteristics favor the osseointegration. Hitherto, the literature reports that all designed reactors are limited to processing a single sample at a time. A second limitation of the existing reactors, in terms of geometry, is the difficulty to obtain a uniform treatment on poly faceted pieces. In this context, the present study aimed to design, develop and manufacture a new reactor geometry to surface treatments, scaling it and with better uniformity. The prototype validation was performed through treatments of cylindrical titanium samples in electrolytic bath for 1, 8 and 16 minutes. To characterize the thickness of the coating on the samples, optical microscopy and scanning electronic microscopy were used. For the coating chemical, characterization technique such as energy dispersive spectroscopy, were applied. The wettability study was performed using the sessile drop method. The new reactor designed geometry presented promising results once that it was capable to produce homogeneous, porous hydrophilic coatings, and mechanical resistance to contact. The new reactor has shown ability to scale production. Finally, it is believed that there is a reduction in production costs because the same solution is used to a set of samples.


  1. ALVES JR, C.; GUERRA NETO, C. L. B.; MORAIS, G. H. S.; SILVA, C. F.; HAJEK, V. Nitriding of titanium disks and industrial dental implants using hollow cathode discharge. Surface & Coatings Technology, v. 194, p. 196-202, 2005.
  2. AKTUĞ, S. L. et al. Bioactivity and biocompatibility of hydroxyapatite-based bioceramic coatings on zirconium by plasma electrolytic oxidation. Materials Science and Engineering: C, p. 1020?1027, 2017. ISSN 0928-4931.
  3. BANAKH, O. et al. Synthesis by anodic-spark deposition of Ca- and P-containing films on pure titanium and their biological response. Applied Surface Science, v. 378, p. 207?215, 2016. ISSN 0169-4332.
  4. BAYATI, M. R.; MOSHFEGH, A. Z.; GOLESTANI-FARD, F. Effect of electrical parameters on morphology, chemical composition, and photoactivity of the nano-porous titania layers synthesized by pulse-microarc oxidation.?Electrochimica Acta, v. 55, n. 8, p. 2760?2766, 2010. ISSN 0013-4686.
  5. BECK, U.; LANGE, R.; NEUMANN, H. G. Micro-plasma textured Ti implant surfaces.?Biomolecular Engineering, v. 24, n. 1, p. 47?51, 2007. ISSN 1389-0344.
  6. BECKER, W. et al. Survival rates and bone level changes around porous oxide coated implants.?Clinical implant dentistry and related research, Wiley Online Library, v. 15, n. 5, p. 654?660, 2013.
  7. DEHNAVI, V. et al. Effect of duty cycle and applied current frequency on plasma electrolytic oxidation (PEO) coating growth behavior.?Surface and Coatings Technology, v. 226, p. 100?107, 2013. ISSN 0257-8972
  8. DZHURINSKIY, D. et al. Characterization and corrosion evaluation of TiO2:n-HA coatings on titanium alloy formed by plasma electrolytic oxidation.?Surface and Coatings?Technology, v. 269, n. Supplement C, p. 258?265, 2015.
  9. GOVINDARAJAN, T.; SHANDAS, R. A survey of surface modification techniques for next-generation shape memory polymer stent devices. Multidisciplinary Digital Publishing Institute, p. 2309?2331, 2014.
  10. GOWTHAM, S.; ARUNNELLAIAPPAN, T.; RAMESHBABU, N. An Investigation on Pulsed DC Plasma Electrolytic Oxidation of cp-Ti and its Corrosion Behaviour in Simulated Body Fluid.?Surf. Coat. Technol., v. 301, p. 63?73, 2016.
  11. HARIPRASAD, S. et al. Role of electrolyte additives on in-vitro corrosion behavior of DC plasma electrolytic oxidization coatings formed on Cp-Ti.?Surface and Coatings?Technology, v. 292, p. 20?29, 2016. ISSN 0257-8972.
  12. HENEGAR, A. J. et al. Native oxide transport and removal during atomic layer deposition of tio2 films on gaas (100) surfaces. ACS applied materials & interfaces, ACS Publications, v. 8, n. 3, p. 1667?1675, 2016.
  13. KASEMO, B. Surface Science, vol. 500, p. 656, 2002.
  14. K, V. et al. Role of electrolyte chemistry on electronic and in vitro electrochemical properties of micro-arc oxidized titania films on Cp Ti. Electrochimica Acta, v. 105, n. Supplement C, p. 468?480, 2013. ISSN 0013-4686.
  15. KHANMOHAMMADI, H. et al. The Influence of Current Density and Frequency on the Microstructure and Corrosion Behavior of Plasma Electrolytic Oxidation Coatings on Ti6Al4V. Journal of Materials Engineering and Performance, v. 26, n. 2, p. 931?944, 2017. ISSN 1059-9495.
  16. LI, Q. et al. Correlations between the growth mechanism and properties of micro-arc oxidation coatings on titanium alloy: Effects of electrolytes. Surface and Coatings Technology, v. 316, n. Supplement C, p. 162?170, 2017. ISSN 0257-8972.
  17. LIU, S. et al. Formation mechanism and adhesive strength of a hydroxyapatite/TiO2 composite coating on a titanium surface prepared by micro-arc oxidation. Applied Surface Science, v. 362, n. Supplement C, p. 109?114, 2016. ISSN 0169-4332.
  18. MOHSENI, E.; ZALNEZHAD, E.; BUSHROA, A. R. Comparative investigation on the adhesion of hydroxyapatite coating on ti6al4v implant: A review paper. International Journal of Adhesion and Adhesives, Elsevier, v. 48, p. 238?257, 2014.
  19. MU, M. et al. One-step preparation of TiO2/MoS2 composite coating on Ti6Al4V alloy by plasma electrolytic oxidation and its tribological properties. Surface and Coatings Technology, v. 214, n. Supplement C, p. 124?130, 2013. ISSN 0257-8972.
  20. PAHL, G.; Beitz, W. Engineering Design: A Systematic Approach. Editora Springer Science & Business Media, Ed. 2, 2013. ISBN 1447135814, 9781447135814.
  21. PARFENOV, E. V. et al. Towards smart electrolytic plasma technologies: An overview of methodological approaches to process modelling.?Surface and Coatings Technology, v. 269, n. Supplement C, p. 2?22, 2015. ISSN 0257-8972.
  22. PIRES, A. L. R.; BIERHALZ, A. C. K.; MORAES, A. M.; Biomateriais: Tipos, aplica??es e mercado. Qu?mica Nova, vol. 38, n. 7, p. 957-971, 2015.
  23. PULEO, D.A.; NANCI, A.; Understanding and controlling the bone-implant interface. Biomaterials, v.20, n.23-24, p.2311-2321, 1999.
  24. QIAO, L. P. et al. The entrance mechanism of calcium and phosphorus elements into micro arc oxidation coatings developed on Ti6Al4V alloy. Surface and Coatings Technology, v. 285, n. Supplement C, p. 187?196, 2016. ISSN 0257-8972.
  25. QIU, Z.-Y. et al. Advances in the surface modification techniques of bone-related implants for last 10 years. Regen. Biomater., Oxford University Press, v. 1, n. 1, p. 67?79, nov 2014. ISSN 2056-3418.
  26. RAJ, V., MUBARAK ALI, M. Formation of ceramic alumina nanocomposite coatings on aluminium for enhanced corrosion resistance. Journal of Materials Processing Technology, v. 209, p. 5341?5352, 2009.
  27. SCHWARTZ, Z. & BOYAN, B.D. Underlying mechanisms at the bone-biomaterial interface. J. Cell Biochem., v.56, n.3, p.340-347, 1994.
  28. SHOKOUHFAR, M.; ALLAHKARAM, S. R. Formation mechanism and surface characterization of ceramic composite coatings on pure titanium prepared by micro-arc oxidation in electrolytes containing nanoparticles. Surface and Coatings Technology, v. 291, n. Supplement C, p. 396?405, 2016. ISSN 0257-8972.
  29. SILVA, M. A. M.; GUERRA NETO, C. L. B.; NUNES FILHO, A.; FREITAS, D. O.; BRAZ, D. C.; ALVES JR, C. Influencie of topography on plasma treated titanium surface wettability. Surface & Coatings Technology, v. 235, p. 447-453, 2013.
  30. SOWA, M. et al. Bioactivity of coatings formed on Ti?13Nb?13Zr alloy using plasma electrolytic oxidation. Materials Science and Engineering: C, v. 49, p. 159?173, abr. 2015. ISSN 0928-4931.
  31. SRINIVASAN P. B., BLAWERT C., DIETZEL W. Dry sliding wear behaviour of plasma electrolytic oxidation coated AZ91 cast magnesium alloy, Wear, v. 266, p.1241?1247, 2009.
  32. TRAN, K. T.; NGUYEN, T. D. Lithography based methods to manufacture biomaterials at small scales. J. Sci. Adv. Mater. Devices, Elsevier, v. 2, n. 1, p. 1?14, mar2017. ISSN 24682179.
  33. VENKATESWARLU, K. et al. Role of electrolyte additives on in-vitro electrochemical behavior of micro arc oxidized titania films on Cp Ti. Applied Surface Science, v. 258, n. 18, p. 6853?6863, 2012. ISSN 0169-4332.
  34. WANG, H.-Y. et al. Preparation and properties of plasma electrolytic oxidation coating on sandblasted pure titanium by a combination treatment. Materials Science and Engineering: C, v. 42, n. Supplement C, p. 657?664, set. 2014. ISSN 0928-4931.
  35. WANG, Y. et al. Review of the biocompatibility of micro-arc oxidation coated titanium alloys. Materials & Design, v. 85, n. Supplement C, p. 640?652, nov. 2015. ISSN 0264-1275.
  36. WANG, Y.-H. et al. Dependence of the infrared emissivity on SiC content and microstructure of microarc oxidation ceramic coatings formed in Na 2 SiO 3 electrolyte. Applied Surface Science, jun. 2017.
  37. WHEELER, J. M. et al. Evaluation of micromechanical behaviour of plasma electrolytic oxidation (PEO) coatings on Ti?6Al?4V.?Surface and Coatings Technology, v. 204, n. 21, p. 3399?3409, 2010.
  38. WILLIAMSON, R. S. et al. Effect of duty cycle on the crystallinity, pore size, surface roughness and corrosion resistance of the anodized surface on titanium. Surface and Coatings Technology, v. 277, p. 278?288, 2015. ISSN 0257-8972.
  39. WISMEYER, D.; van WASS, M.; VERMEEREN, J.I. Overdentures supported by ITI implants: A 6,5-year evaluation of patient satisfaction and prosthetic aftercare. Int. J. Oral Maxillofac. Impl., v.10, n.6, p.744-749, 1995.
  40. YAVARI, S. A. et al. Biofunctional surfaces by plasma electrolytic oxidation on titanium biomedical alloys. Surface Engineering, v. 32, n. 6, p. 411?417, 2016. ISSN 0267-0844.
  41. YEUNG, W. K. et al. In vitro biological response of plasma electrolytically oxidized and plasma-sprayed hydroxyapatite coatings on Ti?6Al?4V alloy.?Journal of Biomedical?Materials Research Part B: Applied Biomaterials, v. 101B, n. 6, p. 939?949, 2013.?ISSN 1552-4981.
  42. YEUNG, W. K. Investigation of Plasma Electrolytic Oxidation Processes for Production of Porous Biocompatible Coatings on Ti Alloys. Tese (phd) ? University of Sheffield, mar. 2016.
  43. YU, H.; CHEN, S.; CAO, P. Synergistic bactericidal effects and mechanisms of low intensity ultrasound and antibiotics against bacteria a review. Ultrasonics Sonochemistry, v. 19, n. 3, p. 377?382, maio 2012. ISSN 1873-2828.
  44. ZHAO, Y.; YEUNG, K. W.; CHU, P. K. Functionalization of biomedical materials using plasma and related technologies. Appl. Surf. Sci., North-Holland, v. 310, p. 11?18, aug 2014. ISSN 01694332.
  45. ZHOU, T. et al. Surface functionalization of biomaterials by radical polymerization. Prog. Mater. Sci., Pergamon, v. 83, p. 191?235, oct 2016. ISSN 00796425.

[Ana Karenina de Oliveira Paiva, Arlindo Balbino Nascimento Neto, Andrea Santos Pinheiro de Melo, Angelo Roncalli Oliveira Guerra, Ricardo Alexsandro de Medeiros Valentim and Custodio Leolpodino de Brito Guerra Neto. (2019); A NEW REACTOR GEOMETRY TO TREATMENT IN SCALE OF BIOMEDICAL SURFACES BY PLASMA ELECTROLYTIC OXIDATION. Int. J. of Adv. Res. 7 (Jun). 1012-1029] (ISSN 2320-5407). www.journalijar.com


Ana Karenina de Oliveira Paiva
Federal University of Rio Grande do Norte

DOI:


Article DOI: 10.21474/IJAR01/9306      
DOI URL: http://dx.doi.org/10.21474/IJAR01/9306