BACTERIOLOGICAL QUALITY OF DRINKING WATER AND ASSOCIATED FACTORS AT COMMUNITY POINT SOURCES, IN ARUA DISTRICT, UGANDA
- Abstract
- Cite This Article as
- Corresponding Author
Background: Access to ample and safe water is vital, yet many globally lack this essential resource. Each year, 3.4 million individuals die from water-related diseases. Specifically, in Uganda, annual estimates suggest 89,000 cholera cases, resulting in 3,000 deaths.
Objective: This study aimed to evaluate the bacteriological quality of drinking water and related factors in Arua Districts community water sources.
Method: Utilizing a cross-sectional design and laboratory experiments, 140 samples were analyzed for coliform bacteria presence on filter membranes. Factors relating to contamination risks were identified via a sanitary inspection checklist. Data analysis was conducted using Stata/SE 17.0.
Results: About 70.71% of samples contained bacteria, primarily total coliform. Significant risk factors included defective wastewater drainage (aOR: 19.7[5.34-72.72]), malfunctioning appliance parts (aOR: 10.7[2.52-45.92]), and inadequate or absence of fencing (aOR: 9.2[2.43-34.96]), each with a P-value <0.001.
Conclusion: Ensuring safe drinking water requires treatment, quality monitoring, maintenance of appliances, and proper fencing to reduce bacterial contamination.
[Asiku Norman, Akech Stella Immaculate and Opio Bosco (2024); BACTERIOLOGICAL QUALITY OF DRINKING WATER AND ASSOCIATED FACTORS AT COMMUNITY POINT SOURCES, IN ARUA DISTRICT, UGANDA Int. J. of Adv. Res. (Aug). 924-932] (ISSN 2320-5407). www.journalijar.com
Lira University
Uganda