Abstract

Background: In CBCT, metallic structures can cause artifacts in the images, Since most teeth suspected to have vertical root fractures are endodontically treated and have a metallic post in the root canal, fracture detection may pose a challenge. Aim: This study aimed to determine the diagnostic accuracy of cone beam computed tomography using metal artifact reduction algorithm in detection of vertical root fractures of teeth with metallic posts.Materials and Methods: 120 Single rooted extracted human teeth were obtained and endodonticaly treated then placed in an acrylic block and metallic posts were inserted.After post insertion the teeth roots were divided into 2 groups one with Induced vertical root fractures and the other having intact roots with the posts inserted. Then each tooth was coded and imaged by CBCT with and without using metal artifact reduction algorithm. Results: Using the metal artifact reduction algorithm improved the diagnostic accuracy but with no statistically significant difference. Conclusion: In case of presence of metallic posts, CBCT with metal artifact reduction algorithm can be used to detect vertical root fractures.

Keywords

Article Analytics

References

  1. Bechara B, McMahan CA, Nasseh I, Geha H, Hayek E, Khawam G. Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol, 115: 676?81 (2013).
  2. Bechara, B., Moore, W. S., McMahan, C. A. & Noujeim, M. Metal artefact reduction with cone beam CT: An in vitro study. Dentomaxillofacial Radiol. 41, 248?253 (2012).
  3. Bezerra, I. S. Q., Neves, F. S., Vasconcelos, T. V, Ambrosano, G. M. B., & Freitas, D. Q. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dento Maxillo Facial Radiology, 44(6), 20140428 (2015).
  4. Brady E, Mannocci F, Brown J, Wilson R, Patel S. A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth. Int Endod J , 47: 735?46 (2014).
  5. Cohen S, Berman LH,Blanco L, Bakland L,KimJS. Ademographic analysis of vertical root fractures. J Endod , 32: 1160?3 (2006).
  6. Long H, Zhou Y, Ye N, Liao L, Jian F, Wang Y, et al. Diagnostic accuracy of CBCT tooth fractures: a meta-analysis. J Dent , 42: 240?8 (2014).
  7. Moudi E, Haghanifar S, Madani Z, Alhavaz A, Bijani A, Bagheri M. Assessment of vertical root fracture using cone-beam computed tomography. Imaging Sci Dent , 44: 37?41 (2014).
  8. Tang L, Zhou XD, Wang Y, Zhang L, Zheng QH, Huang DM. Detection of vertical root fracture using cone beam computed tomography: Report of two cases. Dent Traumatol ,27:484-8 (2011).
  9. Tofangchiha, M., Adel, M., Tavakolian, E., Ghaffari, P. & Jabbarian, R. The Effect of Metal Artifacts Reduction Algorithm on Diagnostic Accuracy of Vertical Root Fracture by Cone Beam Computed Tomography , an in Vitro Study. 4, 115?120 (2017).
  10. Varshosaz M, Tavakoli MA, Mostafavi M, Baghban AA. Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study. J Oral Sci , 52: 593?7 (2010).
  11. Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL. Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod , 108: 939?45 (2009).

How to Cite This Article

Islam S. Shaker, Nashwa S. Mohamed and Ahmed M. Abdelsamad. (2017); DIAGNOSTIC ACCURACY OF CONE BEAM COMPUTED TOMOGRAPHY WITH AND WITHOUT METAL ARTIFACT REDUCTION ALGORITHM IN DETECTION OF VERTICAL ROOT FRACTURES OF TEETH WITH METALLIC POSTS., Int. J. of Adv. Res., 5 (11), 682-686, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/5820

Corresponding Author

Islam Shawky Shaker
Assistant lecturer of Oral Radiology Faculty of Dentistry Misr International University