Abstract

Purpose: To evaluate linear dimensional changes of vinylpolysilixane impressions after immersion disinfection. Materials and Methods: A standardized steel master cast fabricated to provide dental replica of two teeth prepared for complete crown with 10-degree convergence one represent canine and other represent molar with edentulous interposed space 42.1 mm. Auto polymerized resin perforated custom tray with 2 mm spacer constructed from master cast. The trays paints with adhesive, and allowed to dry for 60 seconds before obtaining the impressions.Regular body vinylpolysilixane impression material (Elite HD+ regular body zhermack) used for fabrication of 30 impressions. A 20 impressions act as control (10 of them left in atmosphere for 30, 60 minutes and other 10 immersed in distilled water for 30, 60 minutes before pouring). Other 10 impressions (test group) immersed in a glutaraldehyde disinfectant solution (MD 520 impression disinfection) for 30 and 60 minutes. All impression poured with extra hard dental stone. Obtained casts evaluated for linear dimensional changes using a digital caliper. Data tabulated and statistically analyzed using one-way analysis of variance with a significance level set at = 0.05. Results: The highest dimensional change value was recorded after immersion impressions in distilled water for 60 minutes while, the lowest value was recorded after immersion in disinfectant solution for 60 minutes. There is no significant difference in dimensional changes between control groups and test group at both immersion times. Conclusion: Under the limitations of present study, tasted disinfection times (30 minutes & 60 minutes) has no effect on dimensional accuracy of tested impression material.

How to Cite This Article

Nawaf Alsofyniy, Adil Almalki, Al-Thomali Hani, El Sayed Omar and Ammar Shamrani. (2019); EFFECT OF TWO-DISINFECTION TIMES ON DIMENSIONAL ACCURACY OF VINYLPOLYSILOXANE IMPRESSIONS., International Journal of Advanced Research (IJAR), 7 (10), 518-521, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/9859

Corresponding Author

Adil Ayidh Almalki
Taif University Faculty of Dentistry

Article Analytics

References

  1. Pritam P Lad1, Minal Gurjar2, Sachin Gunda3, Vivek Gurjar4, Nandan K Rao5. The Effect of Disinfectants and a Surface Wetting Agent on the Wettability of Elastomeric Impression Materials: An In Vitro Study. Journal of International Oral Health 2015; 7(6):80-83
  2. Usama Nassar*, Carlos Flores-Mir, GiseonHeo, YsidoraTorrealba.The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials. J AdvProsthodont 2017;9:182-7
  3. Wala M. Amina, g, Muna H. Al-Alib, Sandra K. Al Tarawnehc, Sahar Th. Tahad,
  4. Mohamed W. Salehe, Nadia Ereifij. The Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts. J Clin Med Res ? 2009: 1(2):81-89.
  5. Usama Nassar, DDS, MS & Ava K. Chow, RDH, PhD. Surface Detail Reproduction and Effect of Disinfectant and Long-Term Storage on the Dimensional Stability of a Novel Vinyl Polyether Silicone Impression Material. Journal of Prosthodontics 24 (2015) 494?498.
  6. Matyas,N.Dao, A.A, Capto, F.M.Lucatorto: Effect of disinfectants on dimensional accuracy of impression materials J.prosthet.Dent. 1990; 64: 25-31.