FUNCTIONAL AND RADIOLOGICAL OUTCOMES OF DISPLACED MID SHAFT CLAVICLE FRACTURES MANAGED OPERATIVELY BY PRECONTOURED LOCKING PLATE
- Post-Graduate Resident Department of Orthopaedics, Government Medical College, Jammu.
- Senior Resident Department of Orthopaedics, Government Medical College, Jammu.
- Professor and Head, Department of Orthopaedics, Government Medical College, Jammu.
Abstract
Background: Clavicle fracture is commonly managed conservatively but non cosmetic appearance and non union in few cases has led to increase in number of cases being managed operatively. In this study , we studied the functional and radiological outcome of clavicle fracture managed by plating.
Material and Methods: A prospective study was conducted in GMC jammu on 30 patients from March 2020 to March 2021 . Patients were operated with precontoured 3.5mm compression plate over superior aspect of clavicle and patients were followed up at 2, 4, 6, 12 and 24 weeks post operatively.
Results: In our study , mean time for union was 14.7 weeks with no patient reporting non union .Range of motion at shoulder joint was near normal and patients reported high VAS scores.
Conclusion: Open reduction and internal fixation with precontoured compression plate for mid shaft clavicle fracture gives good functional and radiological outcomes with high patient satisfaction rates and without any major complications.
Keywords
How to Cite This Article
Gagandeep Singh, Gagandeep Singh Raina and Sanjeev Gupta (2022); FUNCTIONAL AND RADIOLOGICAL OUTCOMES OF DISPLACED MID SHAFT CLAVICLE FRACTURES MANAGED OPERATIVELY BY PRECONTOURED LOCKING PLATE, International Journal of Advanced Research (IJAR), 10 (07), 414-419, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/15049
Corresponding Author
Article Analytics
This work is licensed under a Creative Commons Attribution 4.0 International License.