Vol. 13 (04) pp. 983-987 DOI: 10.21474/IJAR01/20802

TAMING THE LEAK: SUCCESSFUL COIL EMBOLIZATION OF A DIAGONAL CORONARY ARTERY PERFORATION

5 Downloads 25 Views
Crossref

Abstract

Coronary perforation (CP) is a rare but potentially catastrophic complication of percutaneous coronary intervention (PCI). This report describes a Grade 3 perforation in a diagonal branch following lesion preparation with a non-compliant balloon. The perforation was successfully managed with coil embolization, leading to hemodynamic stabilization and preventing further complications. The case highlights the effectiveness of coil embolization as a minimally invasive solution for perforations in small coronary branches when stenting is not feasible, emphasizing the importance of early recognition and intervention in high-risk PCI procedures.


Keywords

Article Analytics

How to Cite This Article

Ouharakat Youssef, Hajji Kamal, Zaid Kamel, Suman Sharma,Harnish Bhatia, Amit Goel and Naveen Bhamri (2025); TAMING THE LEAK: SUCCESSFUL COIL EMBOLIZATION OF A DIAGONAL CORONARY ARTERY PERFORATION, Int. J. of Adv. Res., 13 (04), 983-987, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/20802

Corresponding Author

OUHARAKAT YOUSSEF
MAX SUPER SPECIALITY HOSPITAL DELHI
Morocco