Vol. 4 (04) pp. 1396-1401 DOI: 10.21474/IJAR01/233

SPECTROPHOTOMETRIC EVALUATION OF MICROLEAKAGE IN CLASS V CAVITY USING NEW GLASS IONOMER CEMENTS: AN IN VITRO STUDY.

  • Postgraduate Student, Department of Conservative Dentistry & Endodontics, Yenepoya Dental College, Deralakatte, Mangalore, Karnataka, India, 575018.
  • Reader, Yenepoya, Dental College, Deralakatte, Mangalore, Karnataka, India, 575018.
  • Reader , Yenepoya, Dental College, Deralakatte, Mangalore, Karnataka, India ,575018.
  • Senior Professor & Head of the Department, Yenepoya Dental College, Deralakatte, Mangalore, Karnataka, India, 575018.
82 Downloads 257 Views
Crossref

Abstract

Objective: The aim of this study was to quantify the marginal leakage of two glass-ionomer cements using spectrophotometer. Method and materials: Standardized class V cavities were prepared on 60 extracted human maxillary permanent first premolars, randomly assigned to two groups of 30 teeth each, group A and group B. Group A was restored with Zirconomer and group B was restored with GC Fuji IX Extra. Teeth were subjected to thermocycling and stained with methylene blue. The microleakage was quantified spectrophotometrically and the data were statistically analyzed with Student t test. Results: Restorations of both the materials showed some microeakage in Class V cavities and there were no significant differences statistically. Conclusion: The sealing ability of GC Fuji IX Extra was much better than Zirconomer and GC Fuji IX Extra exhibit better shade matching compared to Zirconomer at cervical area of the teeth.

Keywords

Article Analytics

How to Cite This Article

Shameera.N.K, Shravan Kini, Prithviraj. K.J and Harish. K. Shetty. (2016); SPECTROPHOTOMETRIC EVALUATION OF MICROLEAKAGE IN CLASS V CAVITY USING NEW GLASS IONOMER CEMENTS: AN IN VITRO STUDY., Int. J. of Adv. Res., 4 (04), 1396-1401, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/233

Corresponding Author

Dr. Shameera. N.K