Vol. 8 (01) pp. 315-322 DOI: 10.21474/IJAR01/10297

PHANTOM RADIOLOGY CHARACTERISTICS OF CACO3 - BASED USING CT - SCAN

  • Mathematic and Science Faculty, Universitas Sumatera Utara, Jl. Biotechnology 1 USU Campus, Medan 20155, Indonesia
  • Royal Prima Hospital, Medan Petisah , North Sumatera, Medan 20118 Indonesia
  • Fakultas Kedokteran Universitas Prima Indonesia Medan Petisah , North Sumatera, Medan 20118 Indonesia
30 Downloads 178 Views
Crossref

Abstract

Phantom replacement of femur based on human CaCO3, CaCl, NaCl, KOH + white cement successfully made. Phantom replacement of the femur in humans is made with 3 variants of composition (x = 0.3 and y = 0.67, x = 0.34 and y = 0.63, and x = 0.4 and y = 0.57) namely x is CaCO3 and y is white cement. Thigh replacement phantom was tested using the GE / Optima 660 brand CT-SCAN with 3 potential different variations namely 80 kV, 100 kV, and 120 kV to see Hounsfield units (HU) in the test sample. Through CT-SCAN test, the highest HU is 2016, which is found in substitute phantom x = 0.3 and y = 0.67 with a potential difference of 80 kV and the lowest HU is 904 found in the replacement phantom variation x = 0.4 and y = 0.57 with 120 kV potential difference, while HU bone in general is +/- 1000.

Keywords

Article Analytics

References

  1. Bontrager, Kenneth L dan John P. Lampignano. 2014. Textbook of Radiographic Positioning and Related Anatomy. St Louis: Elsevier Mosby.
  2. Wibisono, N. I., 2011, Koreksi Geometri Pengukuran Dosis Pada Phantom Menggunakan Metode CTDI, Skripsi, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Indonesia, Depok.
  3. Samuelson DA. 2007. Text Book of Veterinary Histology. China: Elsevier. Page 109-126.
  4. Koval KJ, Zuckerman JD. Handbook Of Fracture.3rdedition.Lippincott Williams & Willkins;2006.Hlm.25,29.
  5. Rasad, Sjahriar. 2013. Radiologi Diagnostik. Balai Penerbit Fakultas Kedokteran Universitas Indonesia: Jakarta.
  6. Rasad, Sjahrir. 2011. Radiologi Diagnostik. Edisi 2. Jakarta: Balai Penerbit FKUI.

How to Cite This Article

Manumpan Sihombing, Syahrul Humaidi, Kerista Tarigan, Muhammad Zaini Afdlan, Ali Napiah, Yolanda Sitompul and Zaher Piavani (2020); PHANTOM RADIOLOGY CHARACTERISTICS OF CACO3 - BASED USING CT - SCAN, Int. J. of Adv. Res., 8 (01), 315-322, ISSN 2320-5407. DOI: https://doi.org/10.21474/IJAR01/10297

Corresponding Author

Manumpan Sihombing
Mathematic and Science Faculty, Universitas Sumatera Utara, Jl. Biotechnology 1 USU Campus, Medan 20155, Indonesia